GlacialPower Inc. was established in April 2006 by a talent engineering team from the Switch Mode Power Supply (SMPS) Industry . The team members of GlacialPower has averagely 12 years rich experience in designing ...
1. AC Input
Parameter
Min.
Nom.
Max.
Vin (115 Vac) 100 Vrms 115 Vrms 135 Vrms
Vin (230 Vac) 200 Vrms 230 Vrms 264 Vrms
Vin Frequency 47Hz 50 / 60 Hz 63Hz
2. Efficiency
78% typically at 50% ROL and 230 Vrms input voltage.
3. DC Output Regulation
Output
Tolerance
Min.
Nom.
Max.
Unit
+5V +/- 5% +4.75 +5.00 +5.25
Volts
+3.3V +/- 5% +3.14 +3.30 +3.47
Volts
+12V1 +/- 5% +11.40 +1.200 +12.60
Volts
+12V2 +/- 5% +11.40 +12.00 +12.60
Volts
-12V +/- 10% -10.80 -12.00 -13.20
Volts
+5Vsb +/- 5% +4.75 +5.00 +5.25
Volts
4. DC Output Load
DC OutPut
+5V
+3.3V
+12V1
+12V2
-12V
+5Vsb
Nominal Output Voltage (V)
5
3.3
12
12
-12
5
Min. Current (A)
0.3
0.3
0.5
0.5
0
0
Max. Current (A)
25
25
18
18
0.6
3
Peak Current (A)
19
19
3.5
Max. Power (W)
125
82.5
216
.......
(Read Entire Description)